Yong Xing Boiler Group Co.,Ltd                                                        Service customer with profession

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsCoal Fired Steam Boiler

Flake Chain Grate Coal Fired Steam Boiler Industrial Water Tube Boiler

Flake Chain Grate Coal Fired Steam Boiler Industrial Water Tube Boiler

    • Flake Chain Grate Coal Fired Steam Boiler Industrial Water Tube Boiler
    • Flake Chain Grate Coal Fired Steam Boiler Industrial Water Tube Boiler
  • Flake Chain Grate Coal Fired Steam Boiler Industrial Water Tube Boiler

    Product Details:

    Place of Origin: HENAN
    Brand Name: YONGXING
    Certification: ISO9001,ISO14001,SGS,BV
    Model Number: DZL/SZL

    Payment & Shipping Terms:

    Minimum Order Quantity: 1set
    Price: negotiable
    Packaging Details: Nude packing,Package with Steel Box,or Wooden Box
    Delivery Time: 10-15days
    Payment Terms: T/T, L/C, Western Union
    Supply Ability: USD1000/SET
    Contact Now
    Detailed Product Description
    Thermal Efficiency: 76.87% Placement Type: Horizontal Type
    Specification: 1,2,4,6,8,10ton Water Circulation: Natural Circulation
    Burner: Riello, Baltur,or Optional Packing: Nude Package,Package With Steel Box,Wooden Box
    Boiler Structure Level: Chain Grate,Single Drum,Threaded Pipe Name: Pulverized Coal Fired Boiler

    Single Drums Water Tube With Flake Chain Grate Industrial Steam Coal Fired Boiler


    The characteristics of the boiler
    1. Prevent cracks. The arch tube and the threaded tobacco tube are used to form the drum, so that the drum is changed from the quasi-steel body to the quasi-elastic body structure, and the tensioning members of the tube plate area are eliminated, thereby reducing the stress. The pipe was changed from two return strokes to a single return stroke, which solved the problem of cracks in the tube sheet.


    2. Prevent boiler casing bulge. Due to the arrangement of the riser row in the lower part of the drum, the dead water area at the bottom of the drum is eliminated, so that the sludge is not easily deposited, and the high temperature zone of the drum can be well cooled, preventing the bulge in the lower part of the boiler shell.


    3.  Improve combustion efficiency. The high-efficiency heat transfer thread pipe is used to obtain the enhanced heat transfer effect, which achieves the characteristics of heating and output of the boiler, and improves the thermal efficiency of the boiler.


    4. Compact. Compared with the same type of boiler, the external dimensions are small, saving the investment in the boiler house infrastructure.


    5. Smokeless ash accumulation. The use of a threaded pipe enhances heat transfer and improves the heat transfer coefficient and thermal efficiency. Since the flue gas is disturbed in the pipe, the pipe is less likely to accumulate ash and acts as a self-cleaning.


    6. The fuel is easy to burn. In the furnace, high-efficiency energy-saving furnace arch with integral heat-resistant concrete is used to improve the coal fire condition. The independent air chamber is adopted to achieve reasonable air distribution, which forms an aerodynamic field favorable for combustion in the furnace, thereby expanding coal. 


    7. Eco-Friendly. The furnace arch and outlet smoke window of the boiler have certain dust removal effects. The original dust emission concentration of the boiler is controlled below the standard to ensure that the boiler dust emission meets environmental protection regulations.

     

    Data sheet 1

    Matching auxiliary Type
    Chain Grate travelling grates OR flake type chain grates
    Induced Draft Fan GY1-18 4#Right 0°
    Electromotor Y 132S-4B3
    Forced Draft Fan 4-72-3.2A Right 315°
    Electromotor Y 90L-2
    Electric Pump JGGC2-8X13
    Electromotor Y 90L-2
    Govenor Stepless speed governor
    Electromotor YCT112-4A
    Ash Extractor Screw type
    Electromotor Y 90S-6
    Dust Collector Multi-tube XTD-1

     

    Data sheet 2

     

                                                                   DZL QUICK INSTALLED BOILER

    Data DZL1-T DZL2-T DZL3-T DZL4-T DZL6-T
    Rated evaporation capacity t/h 1 2 3 4 6
    Rated working pressure MPa 0.7/1.0/1.25 0.7/1.0/1.25 1.0/1.25 1.25/1.6 1.25/1.6
    Rated steam temperature ℃ 170/184/194 170/184/194 184/194 194/204 194/204
    Water-supply temperature ℃ 20 20 20 20 20
    Body Heated area m2 6 54 83.5 115 186
    Economizer Heated area m2 10.56 27.6 41.2 53 87.2
    Chain Grate area m2 2.3 2.3 4.1 4.1 5.85
    Exhaust temperature (℃) 120 120 120 125 125
    Maximum shipping weight ton 19 25 28 32 43
    Dimension(L*W*H)
    mm
    4500×2000×3200 5900×2200×3400 6200×2200×3450 6700×2400×3450 7700×2600×3600

     

    TWO PART ASSEMBLED BOILER
    boiler model Unit SZL6-1.25/1.6-AII SZL8-1.25/1.6-AII SZL10-1.25/1.6-AII SZL12-1.25/1.6-AII SZL15-1.25/1.6-AII SZL20-1.25/1.6-AII SZL25-1.25/1.6-AII
    capacity ton/h 6 8 10 12 15 20 25
    rated pressure Mpa 12.5/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
    rated steam temeperature 193/204 193/204 193/204 193/204 193/204 193/204 193/204
    feed water temperature 105 105 105 105 105 105 105
    radiation area m2 18.19 22.14 25.8 25.8 34.117 53.78 99.21
    convection area m2 121.9 158.86 200.38 250.17 331.616 411.8 457.78
    economizer area m2 53.13 104.64 130.8 174.4/261.1 117.72/117.2 212.4 476.16
    valid grate area m2 7.55 9.34 10.98 12.78 16.24 20.84 24.76
    applicable fuel   COAL COAL COAL COAL COAL COAL COAL
    exhaust gas temperature 165.78/169.85 161/165 160/162 158/150 156.7/159.4 153/159 152/156
    design efficiency % 80.11/79.44 79.95/79.98 80.55/80.28 80.68/80.72 80.48/80.56 81.09/80.77 81.38/81.26
    fuel consumption kg/h 863.28/874.78 1153.42/1161.38 1430.96/1442.74 1714.5/1721.8 2167.89/2164.7 2868.63/2884.7 3551/3556
    max part size for delivery mm 7100*2800*3500
    7300*2540*2330
    7300*3000*3500
    7400*2700*2330
    7600*3200*3500
    7700*2900*2330
    7600*3200*3500
    8500*2900*2330
    7350*3373*3505
    8904*3370*1100
    7814.7*3573*3511
    9439*3768*1100
    8478*2600*2740
    Bulk packing

     

    Flake Chain Grate Coal Fired Steam Boiler Industrial Water Tube Boiler
    Welcome inquiry more specifications if u need.

    Contact Details
    Yong Xing Boiler Group Co.,Ltd

    Contact Person: Bettysun

    Tel: 86-13849050429

    Send your inquiry directly to us (0 / 3000)