Product Details:
Place of Origin: HENAN
Brand Name: YONGXING
Certification: ISO9001,ISO14001,SGS,BV
Model Number: DZL/SZL
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Nude packing,Package with Steel Box,or Wooden Box
Delivery Time: 10-15days
Payment Terms: T/T, L/C, Western Union
Supply Ability: USD1000/SET
Contact Now
Detailed Product Description
Thermal Efficiency: 80.91% Fuel: Coal Or Coal Water Slurry
Color: Gray,Golden,,Orange,Blue Water Circulation: Natural Circulation
Type: DZL/DZH Control: Automatic
High Light:

coal fired water tube boiler

,

coal fired hot water boiler

Automatic Coal Fired Boiler and Coal Boiler with Chain Grate Stoker Steam Boiler in China


Performance characteristics
1. The boiler thermal efficiency is above 77%, which is higher than the standard of General Technical Conditions for Industrial Boilers.


2. Quickly install the factory, after the use of the site, install the valve instrument, drum, induced draft fan, smoke air duct, dust collector and water circuit can run, and has the characteristics of quick start fire.


3. Easy installation and movement can save a lot of infrastructure investment.


4. Combustion coal type, low calorific value ≥17750J/Kg, volatile matter>38.5%, and second-class bituminous coal with ash content ≤32.4%.


Pulverized coal burner structure classification
A pulverized coal burner is a device that feeds pulverized coal into a furnace for combustion.
1. Swirling burner. The primary air carrying pulverized coal and the secondary air without pulverized coal are connected to the burner by different pipes. The pulverized coal and air can be thoroughly mixed and form a recirculation zone. Each boiler can be configured with 4 to 48 burners.


2. DC burner. The nozzle is narrow, and the primary and secondary air do not rotate in the burner. The pulverized coal can be completely burned therein.
The heated surface separates the heated surface from the heated surface and the heated surface. Modern large and medium-sized boilers are constructed of water-cooled walls, whereby the water-cooled wall (ie, the heated surface) absorbs the radiant heat in the furnace to evaporate the water into saturated steam. In order to increase the radiant heating surface without increasing the volume of the furnace, the large boiler can be double-exposed water-cooled wall. The superheated heating surface can be divided into a screen type superheater heating surface arranged on the upper part of the furnace and a convection superheater heating surface arranged in the convection flue. The former absorbs radiant heat in the furnace; the latter absorbs convective heat.


The air preheater is installed at the tail of the boiler flue to recover the residual heat of the flue gas and increase the temperature of the combustion air. For high-parameter, high-capacity boilers to increase hot air temperature (>300℃), it is often necessary to stratify the air preheater and the economizer.

 

Data sheet

Model

Item
DZL1-0.7-T
DZL1-1.0-T
DZL1-1.25-T
DZL2-0.7-T
DZL2-1.0-T
DZL2-1.25-T
DZL4-1.25-T
DZL4-1.6-T
DZL6-1.25-T
DZL6-1.6-T
DZL8-1.25-T
DZL8-1.6-T
DZL10-1.25
DZL10-1.6
Rated evaporation
capacity (t/h)
1 2 4 6 8 10
Working
pressure(Mpa)
0.7/1.0/1.25 0.7/1.0/1.25 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
Rated steam
temperature(℃)
170/184/194 170/184/194 194/204 194/204 194/204 194/204
Feed water
temperature(℃)
20 20 20 20 20 20
Effective area of
grate(m2)
2.22 4.1 5.85 7.95 9.75 10.77
Fuel consumption
(Kg/h)
200 400 800 1200 1600 2010
Exhaust flue gas
temperature(C)
150 150 150 150 150 150
Thermal Efficiency
(%)
82 82 82 82 82 82
Size(m) 5.1x 2.2x 3.0 5.5x 2.3x 3.3 6.6x 2.6x 3.6 8.2x 2.9x 3.8 8.1x 3.1x 3.8 7.7x 3.2x 3.6
8.6x 3.0x 2.6
Weight (t) 17 23 25 35 45 33
28

 

TWO PART ASSEMBLED BOILER
boiler model Unit SZL6-1.25/1.6-AII SZL8-1.25/1.6-AII SZL10-1.25/1.6-AII SZL12-1.25/1.6-AII SZL15-1.25/1.6-AII SZL20-1.25/1.6-AII SZL25-1.25/1.6-AII
capacity ton/h 6 8 10 12 15 20 25
rated pressure Mpa 12.5/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
rated steam temeperature 193/204 193/204 193/204 193/204 193/204 193/204 193/204
feed water temperature 105 105 105 105 105 105 105
radiation area m2 18.19 22.14 25.8 25.8 34.117 53.78 99.21
convection area m2 121.9 158.86 200.38 250.17 331.616 411.8 457.78
economizer area m2 53.13 104.64 130.8 174.4/261.1 117.72/117.2 212.4 476.16
valid grate area m2 7.55 9.34 10.98 12.78 16.24 20.84 24.76
applicable fuel   COAL COAL COAL COAL COAL COAL COAL
exhaust gas temperature 165.78/169.85 161/165 160/162 158/150 156.7/159.4 153/159 152/156
design efficiency % 80.11/79.44 79.95/79.98 80.55/80.28 80.68/80.72 80.48/80.56 81.09/80.77 81.38/81.26
fuel consumption kg/h 863.28/874.78 1153.42/1161.38 1430.96/1442.74 1714.5/1721.8 2167.89/2164.7 2868.63/2884.7 3551/3556
max part size for delivery mm 7100*2800*3500
7300*2540*2330
7300*3000*3500
7400*2700*2330
7600*3200*3500
7700*2900*2330
7600*3200*3500
8500*2900*2330
7350*3373*3505
8904*3370*1100
7814.7*3573*3511
9439*3768*1100
8478*2600*2740
Bulk packing

 

Three - Return Residential Coal Fired Boilers Coal Powered Boiler Easy Installation 0

Description

The coal-fired steam boiler is a horizontal three-return hybrid boiler in which a bundle of threaded tobacco pipes is arranged. A light pipe water cooling wall is installed on the left and right sides of the furnace. The movable grate is equipped with a blower and an induced draft fan for mechanical ventilation.
Fuel combustion process: After the fuel is fully combusted in the furnace, the flame enters the rear part of the body through the flue gas passage of the intermediate furnace wall, and is turned to the front smoke box by the combustion chambers on both sides, and then the front smoke box is folded back into the inner tube bundle. After entering the dust collector through the rear smoke box, it is finally drawn by the induced draft fan through the flue to the chimney and discharged to the atmosphere.

 

Welcome inquiry more specifications if u need

Contact Details
Yong Xing Boiler Group Co.,Ltd

Contact Person: Ms. Bettysun

Tel: 86-13849050429

Send your inquiry directly to us
Other Products