Place of Origin: | HENAN PROVINCE |
Brand Name: | YONGXING |
Certification: | ISO9001,ISO14001,A-CLASS,SGS,BV |
Model Number: | CWNS2.1-95/70-YQ |
Minimum Order Quantity: | 1set |
---|---|
Price: | negotiable |
Packaging Details: | Nude packing+wooden box+steel box ,and etc. |
Delivery Time: | 15-30DAYS |
Payment Terms: | T/T,L/C,Western Union |
Supply Ability: | 1000SETS/MONTH |
Features: | Corrugated Furnace | Fuel: | NATURAL GAS/LPG/CITY GAS ,ETC |
---|---|---|---|
Pressure: | 0 Or 10bar | Burner: | Italy Riello Or Italy Baltur, And Brand Olin |
Boiler Capacity: | 0.35-14MW | Thermal Efficiency: | 92.4%--94.5% |
Control Mode: | Automation | The Return Trip: | Three Return |
Quality: | Strict Quality System | Type: | Horizontal |
Condition: | New | Style: | Horizontal |
Output: | Hot Water | After-sales Service Provided: | Engineers Available To Service Machinery Overseas |
High Light: | diesel fired hot water boiler,horizontal fire tube boiler |
Strong Adaptability Diesel Fired Hot Water Boiler Commercial Corrugated Furnace Iso9001
Hot Water Boiler Commercial introduction
WNS series fuel Hot Water Boiler Commercial is a shell-type three-return wet back fuel (gas) boiler.
The operation process of the Hot Water Boiler Commercial is as follows:
The first return stroke: after the diesel is atomized by the burner, the formed torch is filled in the full-wave furnace, and the radiant heat is transmitted through the wall of the furnace; the high-temperature flue gas generated by the combustion is in the back-combustion chamber.
Convergence, enter the second return, the threaded tobacco pipe bundle zone; after convective heat transfer, the flue gas temperature is gradually reduced and then discharged to the front smokebox, and enters the third return process, the light pipe bundle zone. Eventually, the flue gas enters the chimney and is discharged into the atmosphere.
Technical Features
1. Advanced control technology.
The Hot Water Boiler Commercial adopts the control methods of proportional adjustment, automatic water supply adjustment, program start-stop, automatic operation, etc., and has automatic protection functions such as low water level, high temperature and flame out.
2. High thermal efficiency.
The Hot Water Boiler Commercial is equipped with an internal and external thread heat exchange structure developed by the company. This structure increases the heat exchange area and heat transfer coefficient and improves the heat transfer efficiency.
3. The inner and outer double spiral finned tubes are used for the smoke pipe, which greatly reduces the exhaust temperature of the boiler and improves the recovery efficiency of waste heat.
4. Wide range of applicable fuels. Light diesel oil, heavy oil, natural gas, pipeline gas, liquefied gas, biogas, etc. can all be used as fuel for boilers.
5. The Hot Water Boiler Commercial is equipped with imported burners with reliable quality and long service life. It is also possible to configure a dual fuel burner according to user requirements, thereby increasing the scope of application of the device.
6. The Hot Water Boiler Commercial has novel design, compact structure, convenient transportation and installation, and maximizes cost savings for customers.
7. The inspection hole is flanged to facilitate inspection of the internal combustion of the boiler and post-maintenance.
8. Fully automatic control, the operating interface is simple. At the same time, it has protection functions such as over-load, abnormal flame out, gas pressure and gas leakage. The port for remote monitoring is reserved.
Hot Water Boiler Commercial technical data sheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure/pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) |
60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 |
6000 |
900 0 |
1200 0 |
1800 0 |
2400 0 |
3000 0 |
3600 0 |
4800 0 |
6000 0 |
7200 0 |
900 00 |
1080 00 |
1200 00 |
|
Water supply capacity (t) |
7 | 15 | 22 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | 180 | 225 | 270 | 300 |
Oil water boiler Hot Water Boiler Commercial
Project/model | ZKW0.7-85/60-Y(Q) | ZKW1.05-85/60-Y(Q) | ZKW1.4-85/60-Y(Q) | ZKW1.75-85/60-Y(Q) | ZKW2.1-85/60-Y(Q) | ZKW2.8-85/60-Y(Q) | ZKW3.5-85/60-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated calorific value (Mw/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated calorific value | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel consumption | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m3/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m3/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m3/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
Heat Exchanger | Material/structure | Stainless steel | ||||||
Working pressure (MPa) | 1 | |||||||
Heating | Maximum calorific value | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
Pressure loss | 2.2 | 3 | 2 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (m2) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Special for hot water | Maximum calorific value | twenty four | 36 | 48 | 60 | 72 | 96 | 120 |
Water supply capacity (m3/h) | 6 | 9 | 12 | 15 | 18 | twenty four | 30 | |
Hot water temperature | 50 | |||||||
Pressure loss | 2 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2 | |
Water outlet diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
Voltage | Voltage (V) | 220/380 | ||||||
Total power consumption | 2.2 (2.6) | 3.7 (4.1) | 5.0 (6.5) | 7.5(9) | 11 (2.5) | 15 (16.5) | 18.5(20) | |
Blower power consumption | 2.2 | 3.7 | 5 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Long (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
High (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |
Hot water boiler FAQ:
Dear friend,
Thanks for your time for scanning our products.
We need the following information to confirm the boiler model:
1.Boiler type:Oil/gas Hot Water Boiler Commercial
2.Boiler capacity?
3. Boiler pressure?
4. Boiler application?
After confirming these questions, we will know exactly what boiler will be suitable for you and we will provide you our product details and quotation. Thank u.
It is ok to copy the question and answers directly when sending us the inquiry!
Welcome you any time!
Contact Person: Ms. Bettysun
Tel: 86-13849050429
Quality Best 500 - 20000kg/h Oil Gas Fired Steam Boiler With Original Riello Burner
WNS 15t/h Best Service and Technical Support Industrial Gas Fired Steam Boiler
5 ton industrial gas diesel oil fired steam boiler for pharmaceutical industry
High Efficiency Electric Boiler 0.3-4 T/H Electric Fired Boiler ISO Approved
1-40 Ton Oil Fired Steam Boiler Horizontal Type Spiral Tubes Light Oil Boiler
Horizontal Oil Fired Steam Boiler Water Heating Furnace Oil Fired Boiler
6 T Industrial Biomass Fired Steam Boiler Wood Fired Steam Generators For Electricity
Safe Stable Wood Burning Steam Generator 10 Bar Pressure For Chemistry
Automatic Biomass Fired Steam Boiler Wood Chip Steam Boiler Zero Carbon Emissions