Place of Origin: | HENAN PROVINCE |
Brand Name: | YONGXING |
Certification: | ISO9001,ISO14001,A-CLASS,SGS,BV |
Model Number: | SZS10-30-1.25/1.6-YQ |
Minimum Order Quantity: | 1set |
---|---|
Price: | negotiable |
Packaging Details: | Nude packing+wooden box+steel box ,and etc. |
Delivery Time: | 15-30DAYS |
Payment Terms: | T/T,L/C,Western Union |
Supply Ability: | 1000SETS/MONTH |
FUEL: | NATURAL GAS/LPG/CITY GAS ,ETC | PRESSURE: | 10bar,12.5bar,16bar |
---|---|---|---|
Capacity: | 10t,15t,20t,25t | Circulation: | 3return Or 4 Return |
Name: | Oil Gas Steam Boiler | Save Energy: | Condensing Type |
Structure: | Fire And Water Tube | Efficiency: | >96% |
High Light: | natural gas steam boiler,natural gas fired boiler |
Safety value small size water tube oil gas steam boiler with quality assured for Garment Factory
SZS fuel gas steam boiler -- equipment debugging instructions
Special note: after the equipment starts to work, the heating speed needs to be controlled, and the temperature cannot increase too fast.
Avoid boiler parts by heat is not uniform, produce too much stress, affect the service life of the boiler.
1. Before commissioning, the boiler should be thoroughly inspected (including accessories and pipelines) before supplying water to the boiler.
Discharge valve must be closed and air valves must be opened to allow air to escape before entering the water.
2. Supply water to boiler to normal water level according to the above method.
3. Open the burner (see the operation of the burner with the burner of the relevant information). At this point the burner enters the automatic control stage of the program. Purge, ignition, flameout protection and other automatic realization.
4. When there is a cast iron economizer, the circulation loop with the water tank should be opened. When there is a steel pipe economizer, the recirculation loop should be opened to protect the economizer at startup.
5. When there is superheater, the superheater outlet box of the vent valve, trap should be opened, so that steam cooling superheater.
Only when the main steam valve is opened to formally send steam to the pipe network, can close the superheater outlet box of the vent valve, trap.
Features
1. Full-film water wall structure
The boiler body design, the use of advanced all-water membrane type cold wall structure, the structure of the sealing performance is very good, strong reliability, compared with the traditional body structure, can effectively prevent smoke leakage.
2. Efficient heat exchanger
The steam boiler produced by the company is equipped with the corresponding energy-saving device, so that the condensing heat transfer effect of the boiler is more full, effectively improve the heat transfer efficiency of the boiler, smoke temperature is lower.
3. Wide range of fuel adaptation
The steam boiler produced by the company can be fueled by natural gas, liquefied natural gas, urban gas, biogas, etc., with a wide variety of fuel adaption, and users can choose more flexible fuel to meet the requirements of multi-fuel combustion.
Typical SZS series steam boiler technical parameter list | ||||||
model | SZS10-1.6-QY | SZS15-1.6-QY | SZS20-1.6-QY | SZS25-1.6-QY | SZS35-1.6-QY | SZS45-1.6-QY |
Rated evaporation t/h | 10 | 15 | 20 | 25 | 35 | 45 |
Rated steam pressure MPa | 1.6 | |||||
Rated steam temperature °C | 204 | |||||
Feed water temperature °C | 105 | |||||
Boiler design thermal efficiency% | 93.5%~100.6% | |||||
Common fuel | Natural gas / light diesel | |||||
Combustion method | Forced ventilation, micro-positive pressure combustion | |||||
Exhaust gas temperature °C | 55~150 | |||||
Fuel consumption (natural gas) Nm3/h | 703 | 1055 | 1406 | 1758 | 2461 | 3164 |
Gas supply pressure (natural gas) mbar | 20~30 | 30~50 | 30~50 | 30~50 | 50 | 50~200 |
Maximum transport weight t | 27 | 32 | 37 | 42 | 51 | 35 |
Maximum transport size m | 6.7x3.2x3.5 | 7.2x3.4x3.4 | 7.7x3.6x3.9 | 8.5x3.8x4.1 | 9.6x4.1x4.3 | 10.0x3.5x3.8 |
Mainframe dimensions (including platform, energy saver) | 9.0x5.6x4.4 | 9.9x5.6x4.0 | 10.5x5.7x4.6 | 11.3x6.0x4.8 | 12.4x6.6x5.0 | 13.0x6.8x5.2 |
Description: | ||||||
1. The boiler is mainly designed with natural gas and light diesel oil. It is also suitable for city gas, liquefied petroleum gas, biogas, coke oven gas and mine gas. | ||||||
2. The fuel consumption is calculated based on the calorific value of natural gas 36006KJ/Nm3 and the calorific value of light oil 42705KJ/kg. | ||||||
3. We follow the principle of continuous improvement and improvement of product performance. The data of the new generation products may be changed. The data in the table is for reference only. |
Contact Person: Ms. Bettysun
Tel: 86-13849050429
Quality Best 500 - 20000kg/h Oil Gas Fired Steam Boiler With Original Riello Burner
WNS 15t/h Best Service and Technical Support Industrial Gas Fired Steam Boiler
5 ton industrial gas diesel oil fired steam boiler for pharmaceutical industry
High Efficiency Electric Boiler 0.3-4 T/H Electric Fired Boiler ISO Approved
1-40 Ton Oil Fired Steam Boiler Horizontal Type Spiral Tubes Light Oil Boiler
Horizontal Oil Fired Steam Boiler Water Heating Furnace Oil Fired Boiler
6 T Industrial Biomass Fired Steam Boiler Wood Fired Steam Generators For Electricity
Safe Stable Wood Burning Steam Generator 10 Bar Pressure For Chemistry
Automatic Biomass Fired Steam Boiler Wood Chip Steam Boiler Zero Carbon Emissions