Yong Xing Boiler Group Co.,Ltd                                                        Service customer with profession

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsGas Hot Water Boiler

Horizontal High Efficiency Natural Gas Boiler Low Pressure Steam Boiler

Horizontal High Efficiency Natural Gas Boiler Low Pressure Steam Boiler

  • Horizontal High Efficiency Natural Gas Boiler Low Pressure Steam Boiler
Horizontal High Efficiency Natural Gas Boiler Low Pressure Steam Boiler
Product Details:
Place of Origin: HENAN PROVINCE
Brand Name: YONGXING
Certification: ISO9001,ISO14001,A-CLASS,SGS,BV
Model Number: CWNS2.1-95/70-YQ
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiable
Packaging Details: Nude packing+wooden box+steel box ,and etc.
Delivery Time: 15-30DAYS
Payment Terms: T/T,L/C,Western Union
Supply Ability: 1000SETS/MONTH
Contact Now
Detailed Product Description
FUEL: NATURAL GAS/LPG/CITY GAS ,ETC PRESSURE: 0 Or 10bar
Burner: Italy Riello Or Italy Baltur, And Brand Olin Boiler Capacity: 2.1MW
Boiler Outer Package: Stainless Steel Usage: For Residental
High Light:

low pressure steam boiler

,

gas water furnace

Horizontal Oil/ gas pressure hot water boiler for hotel electric water kettle boiler price

 

CWNS direct heating

1. The CWNS series is a horizontal internal combustion wet-back shell boiler. It consists of a shell, a furnace, a back-burning chamber, a front and rear smoke box, and a fire tube.

2. Small-sized straight furnace, large-sized corrugated furnace, enhanced heat transfer and high thermal efficiency.

3. The back-fired chamber adopts the butt welding process and the wet-back structure, which avoids the disadvantages of the back tube sheet being washed by the high-flux gas flushing weld to ensure the safe operation of the boiler.

4. The boiler is shipped from the factory, and various control systems such as touch screen, PLC program control, and ordinary computer are available.

5. The exterior is packaged in milky white color steel plate, which is beautiful and elegant.

6. Central hot water unit (indirect heating type) modular design: modular central hot water unit, which combines boiler, circulating water pump, valve, instrument, control system and other accessories and software into one module, installed in the factory Complete sets, in the form of units directly used in the heating system linkage system where needed. The function is extensible and meets the multi-faceted selective needs of users.

 

Features:
1. Adopting the normal pressure mode, the boiler is not under pressure, and the safety factor is high, and there is no danger of explosion.
2. Designed as a burner-type pyrotechnic tube boiler, the fuel is burned by the burner in a micro-positive pressure in the furnace, the high-temperature flue gas is radiated and heat-exchanged in the furnace, and then enters the convective heat exchange of the pyrotechnic tube, and finally passes through the upper cigarette case. discharge.
3. The boiler body design of the boiler body adopts computer optimized simulation design, which fully optimizes the size of the boiler and makes the shape harmonious and beautiful.
4. The flue pipe is inserted with a baffle to slow down the flue gas discharge speed, strengthen the heat exchange, ensure the heat generated by the fuel combustion to heat the boiler water to the greatest extent, and greatly improve the thermal efficiency of the boiler.
5, equipped with imported brand burners, fully automatic program control, high degree of automation, the fuel system provides the fuel needed for combustion, the air supply system sends the appropriate wind speed, air volume, the ignition system ignites the mixture of air and fuel, the detection system Ensure stable and safe combustion of the burner
6. The gap between the large diameter pipe and the large hole bridge makes the scale coating thin and easy to clean in the same time. Product map
7, the shell shell furnace large interlayer water jacket, the boiler water capacity is large, can provide sufficient boiling water.
8, with multiple safety protection: leakage protection means that leakage automatically cuts off the power supply; overheat protection means that when the boiler water temperature reaches the alarm temperature, the burner is automatically stopped and an alarm is issued; when the secondary overheat protection means that the temperature of the boiler casing exceeds 105 °C, it is automatically cut off. The secondary circuit, the boiler stops working; the water level detection protection uses the sophisticated water level electrode rod to monitor the water level in real time, and the water level is lower than the upper limit water level solenoid valve until the upper limit water level is reached.
9, mechatronics design, small size, easy to install and transport.
10. The furnace is specially treated to ensure the water quality is clean and hygienic.
11, the outer lining aluminum foil glass wool for insulation, better insulation effect.
12, white color plate packaging, beautiful, clean and rust resistant.
13. The water supply port is at the lower part, the solenoid valve automatically replenishes water, and the boiling water in the boiling water area takes water to eliminate the phenomenon of “hot and cold water” and “thousand boiling water” to ensure that 100% of the drinking water is pure boiling water. 14. The boiler can be used in two machines, which can supply boiling water and provide hot water.

Horizontal High Efficiency Natural Gas Boiler Low Pressure Steam Boiler 0

Oil water boiler 0.35MW-14MW Oil Gas Fired hot water boiler technical datasheet

Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler
Project model CWNS, WNS series hot water boiler
Rated calorific value (MW) 0.35 0.7 1.05 1.4 2.1 2.8 3.5 4.2 5.6 7 8.4 10.5 12.6 14
Working pressure (MPa) Normal pressure / pressure
Outlet water temperature (°C) 85/115

Backwater temperature (°C)

60/70
Boiler thermal efficiency (%) 91—95
Feed water temperature (°C) 20
Fuel consumption Diesel (Kg/h) 32 65.4 98 131 196.2 261.6 327 392.4 523.2 654 784.8 981 1177 1310
Heavy oil (Kg/h) 34 69.5 105 139 208.5 278 347.5 417 556 695 864 1042.5 1251 1390
Natural gas (m3/h) 39.5 79.3 119 159 237.9 317.2 396.5 475.8 644 793 951.6 1189.5 1427.4 1586
Liquefied gas (m3/h) 14.2 29 43.5 58 87 116 145 174 232 290 348 435 522 580
City gas (m3/h) 84 168.5 253 337 505.5 674 842.5 1011 1348 1685 2022 2527.5 3033 3370
Boiler transportation Length (mm) 2800 3500 4100 4500 4700 4550 5700 6300 7000 7200 7840 8100 8230 8250
Width (mm) 1600 1600 1900 2000 2110 2210 2500 2600 2700 2800 2860 3100 3100 3400
High (mm) 2000 2100 2310 2360 2470 2580 2800 2900 3200 3300 3300 3400 3400 3550
Total power consumption (KW) 2.3 6.7 11 13.5 19 21 23.5 26 37 37 42 45 52 52
Chimney diameter (mm) 250 350 430 450 450 550 650 650 650 800 800 900 1200 1200
Shipping weight (T) 3.2 4.7 4.8 5.4 8 9.78 13.4 15.4 17.4 17.4 23.8 30 31.6 34.5
Heating area (m2) 3000

6000

900

0

1200

0

1800

0

2400

0

3000

0

3600

0

4800

0

6000

0

7200

0

900

00

1080

00

1200

00

Water supply capacity (t)

7 15 22 30 45 60 75 90 120 150 180 225 270 300

 

Oil water boiler Vocume hot water boiler

 

Project / model ZKW0.7-85/60-Y(Q) ZKW1.05-85/60-Y(Q) ZKW1.4-85/60-Y(Q) ZKW1.75-85/60-Y(Q) ZKW2.1-85/60-Y(Q) ZKW2.8-85/60-Y(Q) ZKW3.5-85/60-Y(Q)
Heat medium water capacity (L) 410 520 568 700 830 980 1250
Rated calorific value (Mw/h) 0.7 1.05 1.4 1.75 2.1 2.8 3.5
Rated calorific value 60 90 120 150 180 240 300
Fuel consumption Light diesel oil (Kg/h) 64 96 128 160 192 256 320
Heavy oil (Kg/h) 67.3 100 134 168 202 269 363
Natural gas (m3/h) 165 116 155 193 232 310 387
City gas (m3/h) 77 247 330 412 494 659 824
Liquefied gas (m3/h) 29 44 58 73 88 117 146
Heat Exchanger Material/structure Stainless steel
Working pressure (MPa) 1
Heating Maximum calorific value 36 54 72 90 108 144 180
Warm water circulation 36 54 72 90 108 144 180
Pressure loss 2.2 3 2 2.6 2.5 3.5 3.3
Heating outlet (DN) 65 80 80 100 125 125 133
Heating area (m2) 6000 9000 12000 15000 18000 24000 30000
Special for hot water Maximum calorific value twenty four 36 48 60 72 96 120
Water supply capacity (m3/h) 6 9 12 15 18 twenty four 30
Hot water temperature 50
Pressure loss 2 0.6 1.5 1.8 1.5 1.8 2
Water outlet diameter (DN) 40 65 65 80 100 100 125
Voltage Voltage (V) 220/380
Total power consumption 2.2 (2.6) 3.7 (4.1) 5.0 (6.5) 7.5(9) 11 (2.5) 15 (16.5) 18.5(20)
Blower power consumption 2.2 3.7 5 7.5 11 15 18.5
Oil pump power consumption 0.4 0.4 1.5 1.5 1.5 1.5 1.5
size Chimney diameter (mm) 350 350 400 450 500 550 600
Long (m) 2700 3200 3400 4050 4700 4900 5500
Width (m) 1365 1365 1600 1600 1600 1800 2020
High (m) 2345 2400 2500 2580 2580 2630 2700

Contact Details
Yong Xing Boiler Group Co.,Ltd

Contact Person: Ms. Bettysun

Tel: 86-13849050429

Send your inquiry directly to us
Other Products